2-PANEL REVERSIBLE ASSEMBLY INSTUCTIONS
(STANDARD ASSEMBLY) |
 |
| 1 |
 |
Assemble frame using 1" selfthreading
screws into extruded slots on head and sill.
IMPORTANT: Place bead
of caulking at the full joint of the jambs
and sill and turn screws tight.
NOTE: The weatherstripping on the jambs should face to the exterior
side. Please insure that the jambs are installed
on the correct side. The jamb weatherstripping
channel notch that is the shortest, installs
to the sill. Inspect to insure proper assembly. |
 |
 |
|
 |
| 2 |
 |
 |
 |
Thoroughly clean sill area. Locate frame
in opening. Make sure sill rests as solidly
as possible on floor.
Allow space at both sides to plumb jambs. Aluminum
jambs are handed, impossible to assemble inside
to out, and universal to receive either left
slide or right slide.
NOTE: The weatherstripping on the jambs should face to the exterior
side.
Please be sure that the jambs are installed on the correct side.
The jamb weatherstripping channel notch that
is the shortest, installs to the sill. Inspect
to insure proper assembly. |
|
 |
| 3 |
 |
Secure sill with #10 wood screws provided.
Shim to level if necessary. Caulk against
water leakage under sill using flashing or
caulking as required.
Caulk all installation holes in sill prior ro screw installation. |
 |
 |
|
 |
| 4 |
 |
 |
 |
Fasten jambs with 1 1/2" wood screws
provided. Shim tightly behind screws to plumb.
Caulk holes prior to installing screws.
2 Panel Units:
Install black PVC jamb wedge guide in outside
frame channel at pre-drilled hole location
nearest strike jamb lock fabrication, as
shown.
|
|
 |
 |
 |
HP UNIT ONLY FOR COASTAL APPLICATIONS
Two panel units: Drill a 5/32" hole to install an additional panel wedge
guide. Locate approximately 3" from the base of frame.
|
|
 |
| 5 |
 |
Secure head with 1 1/2" wood screws provided. |
|
 |
| 6 |
 |
 |
 |
PANELS ARE REVERSIBLE:
To reverse fixed panel, simply turn top to bottom.
Keep weathertripping facing exterior. |
|
 |
| 7 |
 |
To reverse sliding panel, remove interlock
and replace after rotating.
Sliding panels are assembled to latch on left side
(viewed from exterior) |
 |
 |
|
 |
| 8 |
 |
Remove mortar, sand or dirt from frame
track prior to panel installation.
Install styro-closure in fixed jamb (as shown).
Butt styro-closure against sill.
DO NOT CUT STYRO-CLOSURE
The remainder seals head after panel installation. |
 |
 |
|
 |
| 9 |
 |
Install two (2) PVC spreader clips at
top and bottom of fixed panel.
Snap into channel (use a mallet if necessary) at 1/3 points:
Make certain clip extension projects towards exterior, as shown
in diagram.
PVC spreader clip
(typical top/bottom)
|
 |
 |
|
 |
| 10 |
 |
 |
 |
Insert the top of the fixed panel into
the inside channel of the head with the weatherstripping
on the fixed interlock facing the exterior.
Fit the bottom of the fixed panel into the channel of the sill.
Push the fixed panel firmly into the jamb.
Caulk the fixed interlock at the bottom of the panel where it contacts
the silll.
(As shown)
|
|
 |
| 11 |
 |
Remaining styro-closure to fit snugly
against fixed interlock.
Press between fixed panel and frame (as shown) |
 |
 |
|
 |
| 12 |
 |
HP UNIT ONLY
NOTE: For coastal applications
At the lock jamb end of the threshold, the gap between the threshold
and the jamb must be plugged and sealed.
A 1" long piece of 5/8" styro-closure will
be suitable. |
 |
 |
|
 |
| 13 |
 |
 |
 |
IMPORTANT: If closures appear too long,
make certain fixed panel is well seated into
jamb.
Break off weather-stripping fin of head and sill closures at JAMB
SIDES ONLY.
NOTE: On 4-panel unit, DO NOT break off weather-stripping fin.
Seal at each end of the aluminum threshold:
A) At fixed panel interlock
B) At Lock jamb
|
|
 |
| 14 |
 |
Insert top of sliding panel (with nylon
guide rollers) into outside channel of head
with weather-stripping on interlock facing
interior.
(Reverse interlock, if necessary, as shown in step 7.)
Swing panel into vertical position lacing rollers on sill track. |
 |
 |
|
 |
| 15 |
 |
 |
 |
Close sliding panel to jamb and align
by adjusting bottom rollers.
Slide panel full length of frame to check for scraping or binding
at head of sill.
Adjust rollers to correct, if necessary. |
|
 |
| 16 |
 |
Install bumper(s) into the non-locking
jamb opposite of the sliding panel.
NOTE: Install two bumpers on 4 panel units.
|
 |

|
|
 |
| 17 |
 |
HP UNIT ONLY
NOTE: For coastal applications
After panel assembly, install angle restrictor to sill, centering
on HP interlock stile. The vertical leg of
the angle restrictor fits into the slot at
the base of the HP interlock stile.
Locate immediately adjacent to the interior edge of the slot, leaving
just enough room, so as to not restrict panel
movement. Attach angle to sill with #10 flat
head screws. |
 |
 |
|
 |
| 18 |
 |
HP UNIT ONLY
NOTE: For coastal applications
Secure fixed panel to frame by installing two (2) 3/16" large flange
rivets through the sill flange into the fixed
interlock. Repeat for head flange using a single large flange rivet
centered over interlock.
NOTE: Sill ad head flange are to be drilled for a 3/16" large flange
rivet. Use a #11 drill bit to create a hole
size of 0.192-0.196. Caulk holes prior to
rivet installation. |
 |
 |
|
 |
| 19 |
 |
HP UNIT ONLY
Seal between sill riser leg and bottom rail of fixed panel and vertically
up the jambs at the fixed panel for 2".
|
 |
 |
|
 |